Business Continuity During a Cyber Incident
IT said wait. The ransomware did not.
What Is Business Continuity During a Cyber Incident?
When ransomware hits the office network, a plant still linked to it is part of the same incident. You wait for IT the way you were told, and watch the encryption reach the control system. Then you follow the manual-operations procedure: cut the IT/OT link, run the process by hand, record each decision with its time, and keep the link out until a clean restore. You finish able to keep an essential service running while the systems recover.
What You'll Learn in Business Continuity During a Cyber Incident
- Explain why an office IT incident threatens a plant that stays linked to the office network.
- Isolate the operational network from office IT as the continuity procedure directs.
- Keep an essential service running on manual operation and local control.
- Record every continuity decision with its time for the incident record.
- Decide when reconnecting is safe, only after a clean restore from backup.
Business Continuity During a Cyber Incident — Training Steps
-
The Office Is Hit
Alice is shift lead in the Kelby control room of Holmsford Water. Jonah Pell is on shift beside her. A message from IT about ransomware lands on her console.
-
Standing By
The plant looks normal on the mimic, so Alice does what the message asks and waits. Reply the way it happened: this is the mistake the rest of the exercise is about.
-
The Alarm
The beacon over the mimic is flashing. A basin and its line have turned red, and pump 2 has tripped.
-
The Duty Line
The duty line is ringing. It is Mira Ellison, the CISO, with what has happened on the plant side.
-
The Procedure
The manual-operations procedure is the binder on Alice's console. Its first page is the order to work in when office IT is compromised. Cut the IT/OT link, go to manual, run the pumps locally, log every decision.
-
Cutting the Link
OT, operational technology, is the equipment that runs the process. The patch lead in the network cabinet is the one link between it and the office. Pull it, and the plant runs on its own.
-
Manual Operation
The firewall light is amber: the plant is islanded. Now the plant goes into manual operation, and someone has to watch the levels. Jonah is waiting for a job.
-
Pump 2 by Hand
Pump 2 tripped when the SCADA server went down. Its local panel in the pump hall can run it without SCADA. Switch it to hand control.
-
Water Still Flowing
An amber frame round the mimic means manual operation. Water is running along the pipes to the Upper Kelby reservoir again.
Security Framework Coverage
CIS Controls
- CIS 17 Incident Response Management
NIST CSF
- PR.AT-01 Personnel are provided with awareness and training so that they possess the knowledge and skills to perform general tasks with cybersecurity risks in mind
- RS.MA Incident Management
NICE Framework
- OG-WRL-002 Cybersecurity Policy and Planning
- PD-WRL-003 Incident Response
NIS2
- Art. 21 Cybersecurity risk-management measures: business continuity and crisis management, point (2)(c)
- Art. 23 Reporting obligations